Dasharo Compatibility: Power State After Power Failure
PSF001.001 Check Power State After Power Failure default state (firmware)
Test description
This BIOS setup feature allows users to determine the system's power state after a power failure. Users can choose between restoring the previous power state or always returning to a powered off state. This test ensures that the option is present, and the default state of this option after flashing is correct.
Test configuration data
FIRMWARE
= Dasharo
Test setup
- Proceed with the Generic test setup: firmware.
Test steps
- Power on the DUT.
- While the DUT is booting, hold the
BIOS_SETUP_KEY
to enter the UEFI Setup Menu. - Enter the
Dasharo System Features
menu using the arrow keys and Enter. - Enter the
Power Management Options
submenu. - Verify the
Power state after power failure
field.
Expected result
The Power state after power failure
field should inform that the current
Power state after power failure is Powered Off
.
PSF002.001 Powered Off State Restoration Test
Test description
This test verifies that the Powered Off
setting works correctly. After we
cut and restore power, the machine should not power on by itself.
Test configuration data
FIRMWARE
= Dasharo
Test setup
- Proceed with the Generic test setup: firmware.
Test steps
- Power on the DUT.
- While the DUT is booting, hold the
BIOS_SETUP_KEY
to enter the UEFI Setup Menu. - Enter the
Dasharo System Features
menu using the arrow keys and Enter. - Enter the
Power Management Options
submenu. - Set the
Power state after power failure
field toPowered Off
. - Simulate a power failure by cutting power to the system.
- Restore power and verify that the system does not attempt to start on its own.
- Note the results.
Expected result
The system should remain in the power off state upon power restoration.
PSF003.001 Powered On State Restoration Test
Test description
This test verifies that the Powered On
setting works correctly. After we
cut and restore power, the machine should not power on by itself.
Test configuration data
FIRMWARE
= Dasharo
Test setup
- Proceed with the Generic test setup: firmware.
Test steps
- Power on the DUT.
- While the DUT is booting, hold the
BIOS_SETUP_KEY
to enter the UEFI Setup Menu. - Enter the
Dasharo System Features
menu using the arrow keys and Enter. - Enter the
Power Management Options
submenu. - Set the
Power state after power failure
field toPowered On
. - Simulate a power failure by cutting power to the system.
- Restore power and verify that the system attempts to power on without any external prompt.
- Note the results.
Expected result
The system should attempt to power on upon power restoration.
PSF004.001 Previous Power State Restoration Test - Powered Off
Test description
This test verifies that the The state at the moment of power failure
setting
works correctly if the machine was powered off prior to the failure. After we
cut and restore power, the machine should remain powered off.
Test configuration data
FIRMWARE
= Dasharo
Test setup
- Proceed with the Generic test setup: firmware.
Test steps
- Power on the DUT.
- While the DUT is booting, hold the
BIOS_SETUP_KEY
to enter the UEFI Setup Menu. - Enter the
Dasharo System Features
menu using the arrow keys and Enter. - Enter the
Power Management Options
submenu. - Set the
Power state after power failure
field toThe state at the moment of power failure
. - Power off the DUT.
- Simulate a power failure by cutting power to the system.
- Restore power and verify that the system does not attempt to start on its own.
- Note the results.
Expected result
The system should remain in the powered off state upon power restoration.
PSF004.002 Previous Power State Restoration Test - Powered On
Test description
This test verifies that the The state at the moment of power failure
setting
works correctly if the machine was powered on prior to the failure. After
we cut and restore power, the machine should attempt to power on without any
external prompt.
Test configuration data
FIRMWARE
= Dasharo
Test setup
- Proceed with the Generic test setup: firmware.
Test steps
- Power on the DUT.
- While the DUT is booting, hold the
BIOS_SETUP_KEY
to enter the UEFI Setup Menu. - Enter the
Dasharo System Features
menu using the arrow keys and Enter. - Enter the
Power Management Options
submenu. - Set the
Power state after power failure
field toThe state at the moment of power failure
. - Do not power off the DUT.
- Simulate a power failure by cutting power to the system.
- Restore power and verify that the system attempts to power on without any external prompt.
- Note the results.
Expected result
The system should attempt to power on upon power restoration.